SIMULATION



  1. WRITE THE PROGRAM .
  2. SELECT         [ EDIT ]  SOFT KEY
  3. SELECT         [ REMEMBER ]  SOFT KEY
  4. SELECT         [ EXCUTE ]        SOFT KEY
  5. SELECT         [ PROGRAME CONTROL ] SOFT KEY
  6. ACTIVATE     [ PROGRAME TEST ]  & [ DRY RUNFEEDRATE ]  SOFT KEY
  7. SELECT         [ REAL SIMULATION ] SOFT KEY
  8. SELECT         [ DELETE WINDOW ]   SOFT KEY
  9. SELECT         [ AUTO MODE ] KEY ON MCP 
  10. PRESS            [ RESET ] KEY ON MCP
  11. PRESS            [ CYCLE START ] KEY
  12. INCREASE  FEEDRATE  TO MAXIMUM






PROGRAME  RUN PROCEEDURE


  1. FRIST CLAMP THE JOB PROPERLY.
  2. DO DATUM SETTING AS PER DRAWING.
  3. DO TOOL OFFSET.
  4. WRITE THE PROGRAME.
  5. SIMULATE THE PROGRAME.
  6. DEACTIVATE  [ PROGRAME TEST ]  & [ DRY RUN FEEDRATE].
  7. SELECT  [ AUTO MODE].
  8. SELECT  PROGRAME.
  9. EXCUTE THE PROGRAME.
  10. PRESS [ RESET ].
  11. FEEDRATE REDUCED TO ZERO.
  12. PRESS  [  CYCLE START ].
  13. INCREASE THE FEEDRATE AS PER OUR REQUIREMENT.